PROStart ballasts provide optimum
starting conditions to provide up to
100,000 switching cycles for use on
occupancy sensors and building
control systems.
QUICKSENSE ballast technology
helps to protect against over-
heated bases and sockets, as
well as cracking of the glass wall,
and uses dynamic end-of-lamp-
life sensing, over the entire
dimming range, to avoid false
shutdowns caused by some static
sensing methods. QUICKSENSE
ballast technology will auto-reset
when the end-of-life lamps are
replaced with new ones.
SYSTEM PHO-DIM comes in a
30 x 30 mm profile, and PENTRON
lamps are designed to provide
peak performance at 35°C fixture
ambient, allowing for smaller and
more innovative fixtures.
A complete OSRAM SYLVANIA
System Performance Guide
showing performance character-
istics of lamps and ballasts is
available upon request.
Lamp/Ballast Guide
Key System Features
System Information
100–1% Dimming range
QUICKSENSE
®
ballast technology
(end-of-lamp-life sensing)
PROStart
®
programmed start
ballast
QUICK 60+
®
warranty
1–10V Control
Anti-flash circuitry—turns on in
dimmed mode
High luminous efficacy
Virtually eliminates lamp flicker
High power factor
Low harmonic distortion
Lightweight
UL, CSA, FCC
SYLVANIA
QUICKTRONIC PHO-DIM
is ideally suited for:
Commercial
Retail
Hospitality
Institutional
New Construction
Direct Lighting
Indirect Lighting
Surface Mount
Cove Lighting
Application Information
54W T5 – PENTRON
®
HO
1-lamp QT1x54PHO-DIM
2-lamp QT2x54PHO-DIM
Also operates:
FT55DL, FPC55
SYLVANIA QUICKTRONIC
PHO-DIM operates PENTRON
HO, PENTRON HO Circline, and
DULUX
®
L T5 lamps over a wide
(100–1%) dimming range.
SYSTEM PHO-DIM provides
nearly twice the light output
(188%) of T8 systems, with the
same number of lamps, allowing
many new design options. One
lamp fixtures can now be used
in place of two lamp models.
SYSTEM PHO-DIM is appropriate
for lighting control for aesthetic
reasons as well as lighting
management for energy conser-
vation through daylight harvesting
or building automation.
Setting the standard for quality,
SYSTEM PHO-DIM is also
covered by our QUICK 60+
warranty, the first and most
comprehensive system warranty
in the industry.
SYSTEM PHO-DIM is available in
one and two lamp models in 120V
and 277V to cover a wide range
of applications.
QUICKTRONIC
®
HELIOS
T5 HO Dimming (0-10V)
<10% THD Electronic T5 HO Fluorescent Controllable Lighting Systems
10
20
40
50
60
70
80
90
100
Power Input (Watts)
QT2x54PHO-DIM
Light Output (BF)
30110 90 70 50120 100 80 60 40 20
30
0
15
Professional Series
Page view 0
1 2

Summary of Contents

Page 1 - T5 HO Dimming (0-10V)

62PROStart ballasts provide optimumstarting conditions to provide up to100,000 switching cycles for use onoccupancy sensors and buildingcontrol system

Page 2 - Normal Ballast Factor

63OSRAM SYLVANIA National Customer Service and Sales Center1-800-LIGHTBULB (1-800-544-4828)www.sylvania.comStarting Method: ProgrammedStartCircuit Typ

Comments to this Manuals

No comments